会议专题

EXPERIMENTAL RESEARCH ON MECHANICAL PROPERTY OF BEAM-COLUMN ENDPLATE CONNECTIONS FOR PORTAL FRAME

8 beam-column endplate connections of portal frame with different details were studied by monotonic loading experiments. The characters of joint rotational stiffness,moment resistance,and rotational capacity influenced by endplate or column flange thickness,rib stiffener,extended or flush types were tested. The results show that setting rib stiffener in joint panel zone is essential to increase the bearing capacity for joints the bearing capacity of which is determined by buckling of joint panel zone. Connections without thickening the endplate or column flange reflect semi-rigid property. Such features are more obvious for flush type connections comparing extended ones. To simply thicken the endplate will not distinctly change the mechanical properties for the connections whose endplate and column flange are both non-thickened.

Jian YE Wei Zhang Jian Xia Canglin Lai Wenyao Zhang

Fujian Academy of Building Research,Fuzhou,Fujian,350025,P.R.China Fujian Academy of Building Research,Fuzhou,Fujian,350025,P.R.China College of Civil Engineering,Fuzh

国际会议

The International Symposium on Innovation & Sustainability of Structures in Civil Engineering(2011年土木工程结构创新与可持续发展国际会议)

厦门

英文

1190-1195

2011-10-28(万方平台首次上网日期,不代表论文的发表时间)