Experimental Study of Electrical Characteristics on Pantograph Arcing
Perfect sliding electrical contact between pantograph and catenary can guarantee the safety and stability of locomotive. Pantograph arcing is one of the main factors of sliding electrical contact performance in electrified railway system. The main reason of pantograph arcing is the varying gap due to the mechanical vibration between pantograph and catenary, so it is important to study of electrical characteristics on pantograph arcing. In this paper, pantograph arcing experiments are carried out using a novel test apparatus of pantograph arcing, the electrical characteristics are analyzed; arcing voltage and current have a lot of DC and harmonic component. Arcing current has large overshoot when the pantograph arcing start burning, then that according to regular changes in the sinusoidal, arcing voltage has rapid decline when the pantograph arcing start burning, then that was slight change.
Wangang Wang Guangning Wu Guoqiang Gao Bo Wang Lijun Zhou Yi Cui Donglai Liu
Chengdu Textile College Chengdu, China School of Electrical Engineering Southwest Jiaotong Universit School of Electrical Engineering Southwest Jiaotong University Chengdu, China
国际会议
西安
英文
602-607
2011-10-23(万方平台首次上网日期,不代表论文的发表时间)