会议专题

Pilot Studies on Cloth Media Filter Applied in WWTP for the treatment of Secondary Effluent

Cloth media filter was applied in the treatment of the effluent of a municipal wastewater plant through pilot scale test for water reuse. Ferric chloride (FeCl3), PAFC and polyaluminum chloride (PAC) were employed as coagulants respectively to carry out the test. The average removal efficiency of TP and CODo was 28.76% and 8% after cloth media filter without coagulation, and TP removal was influenced by the influent water quality. However, precoagulation with coagulants of ferric chloride, PAFC, PAC, the average removal efficiency of TP was 63.58%, 60.13%, 66.94% respectively, and no influence of TP removal can be found by the influent water quality. The average removal efficiency of CODCr was increased to 17.7%, 26.3% and 27.7%. TN was removed unstably after cloth media filter.

Sun Shi-quan Bi Li-jun Xu ping-ping Jiang Chang-bo Tan Wan-chun Wu Fang-tong Nie Xiao-bao

School of hydraulic engineering,Changsha University of Science and Technology,Changsha 410076 Urban Construction Department, Zhejiang College of Construction,Hangzhou 311231 School of hydraulic engineering, Changsha University of Science and Technology,Changsha 410076

国际会议

2011 International Conference on Environmental Biotechnology and Materials Engineering(2011年环境生物技术与材料工程国际会议)

哈尔滨

英文

683-689

2011-03-26(万方平台首次上网日期,不代表论文的发表时间)