会议专题

Effect of two-phase contact oxidation on enhanced removal of contaminants in wastewater from copper mine

An improved two -phase contact oxidation adsorption integrated bioreactor (CABR) was used to treat mixed wastewater from copper mine. The CABR was made up of a biofilm reactor and an activated carbon reactor. Polyacrylonitrile balls (20 mm diameter, 260 m2/m3 specific surface, 90% porosity) were filled into the contact oxidation reactor as biofilm attaching materials. Hydraulic residence times (HRT) of the two contact oxidation reactor were 1.5 hr and 1.2 hr, separately. Relevant ratio of aeration and water of the two contact oxidation were 5:1 and 3:1. From the long-term operation, the average removal efficiencies of chemical oxygen demand (COD) and ammonia nitrogen (NH/-N) were 84.1% and 71.3% respectively. Two -phase contact oxidation can achieve the higher removal efficiency and the lower power consumption. Additionally, the activated carbon reactor can significantly remove heavy metal.

Gang Li Keqing Li Lili Liang

Institute of Applied Ecology, Chinese Academy of Sciences, Shenyang 110016, China

国际会议

2011 International Conference on Environmental Biotechnology and Materials Engineering(2011年环境生物技术与材料工程国际会议)

哈尔滨

英文

1404-1407

2011-03-26(万方平台首次上网日期,不代表论文的发表时间)