会议专题

An Extended Error Model for the Mutliport Vector Network Analyzer

An extended error model of n-port vector network analyzer(VNA) is proposed in this paper. With a new error term introduced at each unstimulated port, the imperfect switch effect is fully considered in the model. Especially, the model can be implemented for the VNA with 2n, even n+1 measurement channels under the no-leakage hypothesis. Via calibration procedure, the accurate S parameters of a 4-port device under test(DUT) can be obtained. Experimental verification was carried out through Agilent VNA E5071B, and good agreement is observed.

Hong-Bo Qin Wei Zhao Chun-Hua Yuan Li Qiang Huo-Rong Ren

School of Mechano-Electronic Engineering, Xidian University, Xian, Shanxi, P.R.China, 710071 Nanjing University of Aeronautics and Astronautics, 29 Yudao Street, Nanjing, 210016, P.R.China

国际会议

第九届国际天线、电波传播及电磁理论学术研讨会(ISAPE2010)

广州

英文

1-4

2010-11-29(万方平台首次上网日期,不代表论文的发表时间)