Measurement of Plasma Ion Temperature and Flow Velocity from Chord-Averaged Emission Line Profile

The distinction between Doppler broadening and Doppler shift has been analysed, the differences between Gaussian fitting and the distribution of chord-integral line shape have also been discussed. Local ion temperature and flow velocity have been derived from the chord-averaged emission line profile by a chosen-point Gaussian fitting technique.