A Calibration Technique of 4-port Vector Network Analyzers with a General 12-Term Error Model
A general 2-port block diagram with 12-term error matrixes is presented for the calibration of a 4-port vector network analyzer(VNA). Extending the classical 12-term error model to describe the 4-port network analyzer, all the coefficients in signal paths are replaced by the complex square matrixes and the nodes correspondingly become complex vectors. The scattering matrix can be solved from the forward and reverse general 12-term error model. This is a unified method for the 2-port VNA and 4-port VNA with the same flow graph. Experiment results of a 4-port device attest the good performance of the general 12-term error model.
Quan Sun Wei Zhao Yong-jiu Zhao Duan-wei Zhang Li Qiang
College of Information Science and Technology, Nanjing University of Aeronautics and Astronautics,Na School of Mechatronics Engineering, Xi Dian University, Xi’an, China, 710071
国际会议
南京
英文
1-4
2010-09-20(万方平台首次上网日期,不代表论文的发表时间)