Mouse Atlas conversion for FEM in Fluorescence Tomography Reconstruction

This paper develops a remeshing module to generatevalid meshes for FEM in the application of Fluorescence Tomog-raphyReconstruction (FTR), and it is constructed based on amouse atlas (Digimouse). To our knowledge, few of the recentmesh models have been employed in the area of FTR. In ouralgorithm, the tetrahedron collapse and refinement operations areapplied successively to increase mesh quality and density. Only afraction of the mesh is loaded for tomography reconstruction toreduce memory consumption and computation burden. We showthat the algorithm preserves the mesh quality while increasingthe density of points.

Heng Yang Yannick Glinec Jiwu Zhang

Biomedical Engineering Department,Shanghai Jiao Tong University, Shanghai, 200240, China Global R&D Center,Carestream Health Inc.Building 4,Jinqiao Office Park, No.27 Xin Jinqiao Road, Pudo

国际会议