会议专题

UASB Treatment of Monosodium glutamate Wastewater

Monosodium glutamate (MSG) wastewater is a very refractory case of high strength organic wastewater. To investigate the effect of operating variables on treatment of MSG wastewater, a laboratory scale study was conducted. The treatment of MSG wastewater was studied in a continuous flow anaerobic fluidized blanket (UASB) reactor. The effect of operating variables such as organic volumetric load rate (OLR), pH, volatile fatty acids (VFA) and alkalinity on efficiency of treatment and recovery of biogas was investigated. The results showed that the gas production rate was 3.02 - 8.83 kg COD /m3?d volume load, the gas production rate and COD load volume was positively related; as influent COD in range of 11878 - 16922 mg?l-1, COD removal rate of effluent was in range of 57.00 - 79.63 %; UASB with high acid-base buffering capacity could deal with the acidic organic wastewater (pH<3.5) without adjusting pH.

Yong Gao

School of Chemistry and Environmental Engineering Jiangsu Teachers University of Technology Changzhou, China

国际会议

The 4th International Conference on Bioinformatics and Biomedical Engineering(第四届IEEE生物信息与生物医学工程国际会议 iCBBE 2010)

成都

英文

1-4

2010-06-18(万方平台首次上网日期,不代表论文的发表时间)