Experiment of Dehydration Capability of Municipal Sludge
Sludge is difficult to be dewatered without any pretreatment. The experiment of dewatering sludge by ultrasound, thermal hydrolysis and electrical pretreatment were studied. Ultrasound pretreatment proves it can adjust the structure of sludge, which will be restructure and change the water form increasing the water content which could be dispel easily. Thermal hydrolysis pretreatment disassembles agglomeration of Extracelluar Polymeric Substances (EPS), experimental results show that the bound water of sludge decrease with a longer treatment time and higher temperature, the water content is 84.74% at 170 ℃. The pretreatment of electrical dehydration gains good dewaterability as voltage increased in the AC electric field than ultrasound, thermal hydrolysis pretreatment.
ZHOU Cuihong CHU Qingdong TANG Sichen ZHANG Chenghu
Department of Environmental Engineering Beijing Institute of Pectrochemical Technology Beijing, China 102617
国际会议
成都
英文
1-4
2010-06-18(万方平台首次上网日期,不代表论文的发表时间)