会议专题

Optimization on cleaning in line of hollow fiber membrane module

Based on submerged hollow fiber membrane module operation performance, backwashing pressure (BP) and backwashing flux (BF), the two key parameters of cleaning in line (CIL) operation, were analyzed in this work. The results demonstrated that the optimal CIL condition should made the backwashing solution cover the farthest hollow fiber end. Additional to that, when the module was installed higher than effluent point, it should keep the minimum BP higher than b/K’+H, on the contrary, it should keep the minimum BP higher than b/K’-H when the membrane module position was lower than effluent point. According to the backwashing filtration model of submerged hollow fiber membrane, one backwashing parameter ζ was put forward. When Q’/Pe<ζ, , backwashing solution could not distribute the whole membrane fiber surface, BP and BF should designed content with Q’/Pe>ζ. The numerical simulation of CIL operation showed that, if BP and BF were fixed respectively, the corresponding BP and BF have maximum value region, and the optimal BP and BF could be designed base on this region.

JIA Hui BAI Rui-feng WANG Jie

School of Environmental and Chemical Engineering Engineering, Tianjin Polytechnic University; Key la Siemens Water Technologies and Engineering (TianJin) Co.Ltd.Tianjin 300191, P.R.China

国际会议

The 4th International Conference on Bioinformatics and Biomedical Engineering(第四届IEEE生物信息与生物医学工程国际会议 iCBBE 2010)

成都

英文

1-4

2010-06-18(万方平台首次上网日期,不代表论文的发表时间)