Electricity Generation comparison of two-chamber Microbial fuel cells with different Membranes
In this paper, performance of microbial fuel cell constructed film A, film B and film C, with acetate as carbon source, potassium ferricyanide solution as the electron acceptor, has been studied. The capacity of the microbial fuel cell electrical performance was tested and several membrane microbial fuel cell cost-effective was analyzed. The results show that: maximum volume power density of membrane A is 3.45W/m3, the internal resistance is 56.08.; maximum volume power density of cell with membrane B 3.68W/m3, the internal resistance 49.13.; maximum volume power density of cell with membrane C 8.25W/m3, internal resistance 26.59V. Comparing the performance, film A, film B is a bit weak, but the film A, film B are on the absolute advantage in price. With the membrane indepth study, cost-effective good films for industrial applications in microbial fuel cells is feasible.
Kong Xiaoying Sun yongming Li lianhua Liying Yuan zhenhong kong xiaoying
Biomass Energy Centre Guangzhou Institute of Energy Conversion, C.A.S Guangzhou, 510640, P.R.China Graduate School of CAS,Beijing, 100039, China
国际会议
成都
英文
1-4
2010-06-18(万方平台首次上网日期,不代表论文的发表时间)