会议专题

Effects of Selective Withdrawal on Temeprature of Water Released of Glen Canyon Dam

In order to reduce the negative effect of lowertemperature water released from the intake to the environment in the downstream reach, a selective withdrawal structure will adopted in Glen Canyon Dam. The 3D numerical model EFDC was used to simulate the velocity fields and water temperatures released with surface and lower withdrawal. The numerical results of water temperature released are validated with the measured data. The velocity fields with surface and lower withdrawal indicate that the mainstream of withdrawal water column is located near the elevation of withdrawal intake. Temperatures of water released from the surface and lower withdrawal are simulated for twelve months. The temperatures of water released with a surface withdrawal are effectively enhanced compared with the lower withdrawal.

Shaoxiong Zhang Xueping Gao

Hydraulics Institute Tianjin University Tianjin, China

国际会议

The 4th International Conference on Bioinformatics and Biomedical Engineering(第四届IEEE生物信息与生物医学工程国际会议 iCBBE 2010)

成都

英文

1-4

2010-06-18(万方平台首次上网日期,不代表论文的发表时间)