Study of Numerical Simulation and Experimental of Gas Flow Distribution of Electric Composite Filter Bag in 300MW Power Unit in Coal-fired Power Plant
Using numerical simulation method to calculate conditions of the inner flow field state of a 300MW hybrid electric dust collector bag so that the design of gas flow distribution can meet the demand of electric composite filter bag. Results from the air field test are basically consistent tendency to verify the reliability of numerical simulation methods. The reliability of this method and the feasibility of the gas flow distribution design are demonstrated in the study.
DANG Xiaoqing HU Hongsheng
School of Environmental & Municipal EngineeringXi ’an University of Architecture& TechnologyXi’ an 7 School of Environmental & Municipal Engineering Xi ’an University of Architecture& Technology Xi’ an
国际会议
成都
英文
1-4
2010-06-18(万方平台首次上网日期,不代表论文的发表时间)