Effects of operational parameters on the decolorization of C.I. Acid Blue 9 by Fenton oxidation process
In this paper, advanced oxidation process utilizing Fentons reagent was investigated for degradation of the C.I. Acid Blue 9 from aqueous solution. Some important operation parameters, such as pH value of solutions, iron and hydrogen peroxide concentration, temperature and presence/absence of chloride ion, which effect on the decolorization of the C.I. Acid Blue 9 from aqueous solution by Fenton oxidation have been investigated systematically. The results showed that the optimal reacting conditions were experimentally found to be pH=3.5, H2O2 concentration of 2mmol/L and ferrous concentration of 0.05mmol/L for initial C.I. Acid Blue 9 concentration of 40 mg/L at 30℃. The decolorization rate of C.I. Acid Blue 9 enhanced with the increasing of reaction temperature. Under optimal conditions, 98.25% degradation efficiency of dye in aqueous solution was achieved after 60 minutes of reaction.
Muqing Qiu Qiaoyun Jiang Shoubao Yang Danli Yu Kai Feng
College of Life Science Shaoxing University Shaoxing, P.R.China
国际会议
成都
英文
1-4
2010-06-18(万方平台首次上网日期,不代表论文的发表时间)