会议专题

STUDY THE TOF DETECTOR IN RIBLL WITH GEANT4

We present here an ellipsoidal timing detector in Radioactive Ion Beam Line in Lanzhou (RIBLL). The photons induced by radioactive beam ions passing through a thin plastic-scintillator foil BC422, emit from the foil center corresponding to one focal point of an aluminum ellipsoidal mirror and are reflected to another focus point at which the cathode of a photomultiplier tube locates. A time resolution of about 115ps is achieved for 12 N and the counting rate up to 10 8 pps is allowed. The simulation was carried out using GEANT4 Monte Carlo toolkit. The photons total collection efficiency following projectile from different position, photon collection efficiency and time resolution of photon to photocathode of 3 different cases were calculated. Also the main factors influencing the detectors time resolution and some proposals are given.

Jiaxing Li Denggao Zhang Pingping Liu

School of Physical Science & Technology Southwest University Beibei, Chongqing 400715 China

国际会议

18th International Conference on Nuclear Engineering(第18届国际核能工程大会 ICONE 18)

西安

英文

1-5

2010-05-17(万方平台首次上网日期,不代表论文的发表时间)