THE RELAP5 SIMULATION OF 2 LOCA OF APEX FACILITY

The RELAP5/SCDAP Mod3.2(am5) code is employed to simulate the OSU-AP1000-05 test conducted in the Advanced Plant Experimental (APEX) test facility at Oregon State University (OSU). The APEX-1000 test facility is an one-fourth height, one-half time scale, and reduced pressure integral systems facility to simulate the Westinghouse Advanced Passive 1000 MW (AP1000) pressurized water reactor. OSU-AP1000-05 is a two-inch break at the bottom of cold leg #4 with 3 out of 4 ADS-valves of OSU-APEX-1000 facility. RELAP5 predictions are compared to the experimental data generated by the test. The comparison shows good agreement between the predicted and measured sequence of events of some key parameters during the transient. From the comparison results, it could be preliminary concluded that the RELAP5/SCDAP Mod3.2(am5) code are suitable to simulate the small LOCA of APEX.

Heng Xie

Institute of Nuclear Engineering Technology, Tsinghua University Energy Science Building B-211, Tsinghua Univ., Beijing 100084, P.R.China State Nuclear Power Technology R&D Center