会议专题

The Study of Resolution of X-ray Digital Imaging System Based on the Double Proximity Focusing X-ray Image Intensifier

To the X-ray imaging system, resolution is one of the significant parameters to measure the imaging quality. In order to develop a high-resolution X-ray digital imaging system used for electronic industry, our laboratory has worked out the systemic resolution mathematical model of the X-ray imaging system. In this model, several factors are considered, such as the size of focus of the X-ray source, the double proximity focusing X-ray image intensifier and the influence of CMOS camera. Tests show the model accords with the truth. So it would have some value to the design of the similar systems.

Li Wei Hou Qing

School of Information Engineering Chang an University Xi an, Shaanxi 710064, China Modern Education Technology and Network Center Shaanxi University of Chinese Medicine Xianyang, Shaa

国际会议

2010 International Conference on Optics,Photonics and Energy Engineering(2010光学、光子学与能源工程国际会议 OPEE 2010)

武汉

英文

261-265

2010-05-10(万方平台首次上网日期,不代表论文的发表时间)