会议专题

A Comparison of Power Flow by Different Ordering Schemes

Node ordering algorithms,aiming at keeping sparsity as far as possible,are widely used today.In such algorithms,their influence on the accuracy of the solution is neglected because it wont make significant difference in normal systems.While,along with the development of modern power systems,the problem will become more ill-conditioned and it is necessary to take the accuracy into count during node ordering.In this paper we intend to lay groundwork for the more rationality ordering algorithm which could make reasonable compromising between memory and accuracy.Three schemes of node ordering for different purpose are proposed to compare the performance of the power flow calculation and an example of simple six-node network is discussed detailed.

power flow calculation:node ordering :sparsity accuracy:Newton-Raphson method:linear equations

Wenbo Li Xueshan Han Bo Zhang

The School of Electric Engineering Shandong University Jinan,China

国际会议

2011 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies(第四届电力设施管制、重建及能源技术国际会议 DRPT 2011)

威海

英文

742-745

2011-07-06(万方平台首次上网日期,不代表论文的发表时间)