会议专题

Modeling of Wind Energy Conversion System Using Doubly Fed Induction Generator Equipped Batteries Energy Storage System

in this work the model of different parts of the wind energy conversion system using doubly-fed induction generator (DFIG) is set up and implemented in PSCAD/EMTDC. The two quadrants DC converter using battery energy storage system is employed for the DC-Link Voltage control in normal and fault operating conditions.To verify the control strategies and Low Voltage ride through (LVRT) capabilities a 600 KW DFIG Wind turbine system under 500 ms short circuit fault is tested.Finally,it is proved that the use of battery energy storage system (BESS) improves the power quality during the normal operation and enhances the turbine security level in the grid connected under fault conditions and quickly brings back the stability of the system.

doubly-fed induction generator battery energy storage system:LVRT:grid fault

KONE Ibrahima Chengyong Zhao

School of Electrical and Electronics Engineering North China Electric Power University Beijing,CHINA

国际会议

2011 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies(第四届电力设施管制、重建及能源技术国际会议 DRPT 2011)

威海

英文

1780-1787

2011-07-06(万方平台首次上网日期,不代表论文的发表时间)