Cement Decomposing Furnace Control Based on Diverse Conditions
This paper analyses the factors which affect the outlet temperature of the cement decomposing furnace, considers the condition when the raw material transient feeding is volatile as a special condition, calculates the GM (1,2) model by using the sampling data. Under the special condition, the GM(1,2) model is used to predicte values. While under normal conditions the latest GM (1,1) prediction model is obtained by replacing the old with the new interest rate and calculating the predicted values. Finally the coal feed volume is got by the fuzzy control and the performance is further improved through feedback and correction control.
Gray forecast Typical working condition Fuzzy control Decomposing furnace
Zhang Xiao-xia Wang Xiao-hong Yu Hong-liang
School of Control Science and Engineering, University of Jinan, Jinan 250022, China School of Control Science and Engineering, University of Jinan, Jinan 250022,China School of Control Science and Engineering,University of Jinan, Jinan 250022, China
国际会议
2011 China Control and Decision Conference(2011中国控制与决策会议 CCDC)
四川绵阳
英文
344-349
2011-05-23(万方平台首次上网日期,不代表论文的发表时间)