Study on Electromagnetic Flowmeter for Partially Filled Flow Measurement
An electromagnetic flowmeter with IOng cambered electrodes for partially filled flow measurement is presented in this paper. Principles of this flowmeter for fluid level measurement and flow measurement are discussed and fundamental equations for measurement are derived. Experiment results show that the electromagnetic flowmeter with IOng cambered electrodes can measure fluid level and flow in partially filled pipe.
Electromagnetic flowmeter long cambered electrodes partially filled pipe
Jun Yao Wei Guo Wang Shi Ji
Shanghai Key Laboratory of Power Station Automation Technology, School of Mechanical & Electronic En School of Mechanical & Electronic Engineering and Automation,Shanghai University,Shanghai 200072.Chi Entry-Exit Inspection and Quarantine Bureau. Shanghai 200 135.China
国际会议
2011 China Control and Decision Conference(2011中国控制与决策会议 CCDC)
四川绵阳
英文
3576-3581
2011-05-23(万方平台首次上网日期,不代表论文的发表时间)