会议专题

Thermal Mixing in T-Junctions

Temperature fluctuations occur due to thermal mixing of hot and cold streams in the Tjunctions of the piping system in nuclear power plants. These temperature fluctuations cause thermal fatigue of piping system. In the present work, thermal mixing experiments are carried out on a T-junction with water. Velocity and temperature fields are measured using Hot Film Anemometer (HFA). Also three dimensional steady state Computational Fluid Dynamics (CFD) simulations have been carried out to predict the velocity and temperature fields. The predicted velocity and temperature fields are in good agreement with the experimental measurements.

Temperature fluctuations thermal mixing thermal fatigue HFA CFD

A. W. Patwardhan V. S. Naik-Nimbalkar I. Banerjee G. Padmakumar G. Vaidyanathan

Department of Chemical Engineering,Institute of Chemical Technology, Matunga, Mumbai 400 019, India Indira Gandhi Centre for Atomic Research,Experimental Thermal Hydraulics Section,Separation Technolo

国际会议

The 8th International Topical Meeting on Nuclear Thermal-Hydraulics,Operation and Safety(第八届反应堆热工水力、运行和安全国际会议 NUTHOS-8)

上海

英文

107-117

2010-10-10(万方平台首次上网日期,不代表论文的发表时间)