会议专题

LOFA Analysis of a Modified Liquid-metal Cooled Thermionic Reactor:TOPAZ-II

TOPAZ-II is a liquid-metal cooled space thermionic reactor developed by Russia in 1980s. The liquid-metal coolant loop is driven by a single electromagnetic pump. The electromagnetic pump failure may result in LOFA. Three modified LOFA sequences are analyzed using a thermionic reactor core analytic code-TATRHG(A). The calculations are preliminary. The results show that the reactor can be shut down safely for the third case. Further work needs to be done to do extensively investigation.

TOPAZ-II LOFA

Hu Gu Zhao Shouzhi

China Institute of Atomic Energy P.O.Box 273(33) Beijing, China

国际会议

The 8th International Topical Meeting on Nuclear Thermal-Hydraulics,Operation and Safety(第八届反应堆热工水力、运行和安全国际会议 NUTHOS-8)

上海

英文

238-248