Thermal-Hydraulic System Study of a High Pressure, High Temperature Helium Loop Using RELAP5-3D Code
The thermal-hydraulic system analysis for the Helium Loop Karlsruhe (HELOKA) facility, a high pressure, high temperature experimental helium loop having the European Helium Cooled Pebble Beds Test Blanket Module (HCPB TBM) as test module, is investigated. Using the system code REALP5-3D, all components in the loop are modeled as well as the main control strategy. With this model, the loop dynamics in conditions relevant for blanket module operation are simulated and analyzed.
HELOKA helium loop RELAP5-3D HCPB TBM ITER
X. Jin B.E. Ghidersa
Karlsruhe Institute of Technology (KIT) POB 3640 D-76021 Karlsruhe Germany
国际会议
上海
英文
632-641
2010-10-10(万方平台首次上网日期,不代表论文的发表时间)