会议专题

Sensitivity Study of the Great Size Advanced PWR With the Passive Reactor Make-up Tank

Developing the advanced nuclear power plant design to meet the demanding safety, efficiency and environmental goals of electric utilities requires great efforts. A passive reactor make-up tank (RMT) combined with other active safety systems is introduced into great size advanced PWR designs. The typical accidents are calculated and analyzed for this safety system design, such as SB-LOCA, SGTR, SLB and LOFA. The sensitivity of the RMT with different volumes, and elevations are also studied. It is preliminarily concluded that this safety system design in great size PWR makes a great balance between passive and active safety systems.

PCWA reactor make-up tank advanced accumulator SGTR

Jianhua CAO Xiangang FU Jue YANG Xuenong ZHU Wenhu CHEN Quan GONG Hui QIAN Jing ZHOU

China Nuclear Power Technology Research Institute (CNPRI) 1305, Jiangsu Bldg. A, Yitian Road, Futian Shanghai Branch, China Nuclear Power Design Company, LTD. (Shenzhen) Mechanism Building, 1954 HuaSha

国际会议

The 8th International Topical Meeting on Nuclear Thermal-Hydraulics,Operation and Safety(第八届反应堆热工水力、运行和安全国际会议 NUTHOS-8)

上海

英文

2386-2396

2010-10-10(万方平台首次上网日期,不代表论文的发表时间)