Study of the CPR1000 Containment Over-pressure Fragility Curve and improvement of Containment Filtration and Exhaust System

Based on the results of international researches and design feature of CPR1000 containment, study the fragility curve for CPR1000 containment. The operation pressure to put Containment Filtration and Exhaust System (EUF) into service is proposed. With different operation pressure, the comparison of radiological consequences has been made.

Severe accident fragility curve CPR1000 Containment Filtration And Exhaust System

Jiming LIN Peng CHEN Shishun ZHANG

China Nuclear Power Technology Research Institute (CNPRI) 17/F, Tower A , Jiangsu Building, Yitian Road, Futian District, Shenzhen 518026,Guangdong, P. R. China

国际会议

The 8th International Topical Meeting on Nuclear Thermal-Hydraulics,Operation and Safety(第八届反应堆热工水力、运行和安全国际会议 NUTHOS-8)

上海

英文

2565-2574

2010-10-10(万方平台首次上网日期,不代表论文的发表时间)