Analysis of Nuclear Seawater Desalination Reactor Passive Safety System Facility Emergency Residual Heat Removal Test
This paper builds the numerical model of seawater desalination reactor passive engineered safety features integrated simulation test facility, and then analyzes the impact of the initial accumulator tank water level to the residual heat removal and the establishment of natural circulation in the emergency residual heat removal test. The results coincide with the experimental results well, which proves that RELAP5 code had the calculation and simulation capabilities to integrated simulation test.
Desalination natural circulation emergency residual heat removal RELAP5
Xu Shijie Liu Xun Nie Changhua Zhuo Wenbin Zheng Hua
Nuclear Power Institute of China No.25, third section south, second ring road, ChengDu, China
国际会议
上海
英文
2669-2676
2010-10-10(万方平台首次上网日期,不代表论文的发表时间)