会议专题

A method of flicker measurement based on pisarenko harmonic decomposition

In this paper a novel flicker measurement method is proposed after studying the IEC flicker meter. This method need spectral analyze the wave component to calculate the instantaneous flicker sensation level,and then the pisarenko harmonic decomposition (PHD) is used to obtain the amplitude and the frequency of wave components. To process the wave component by PHD can acquire precise spectrums. The IEC flicker meter and novel method is compared in simulation and test. The result verified the correctness and efficiency of the theoretical prediction.

voltage flicker square demodulation IEC pisarenko harmonic decomposition

DUAN Xiaobo GAO Jun LIANG Zhirui SU Haifeng ZHOU Wen

Hebei Electric Power Institute,Shijiazhuang 050021,China North China Electric Power University,Baoding 071003,China

国际会议

2010年中国国际供电会议(CICED 2010)

南京

英文

714-718

2010-09-13(万方平台首次上网日期,不代表论文的发表时间)