会议专题

A symmetry electrode array for AC and traveling wave Electroosmosis pumping

Using geometry asymmetry, ac electroosmosis (AC EO) experiments are presented on a traveling wave electroosmosis (TW EO) device. To compare AC EO and TWEO, 1.5mS/m KCl electrolysis is selected as pumping solution. AC EO and TW EO flow velocities versus horizontal height were measured, which showed that the flow was generated at the electrodes. The AC EO and TW EO flow velocities depending on voltage and frequency are measured and compared. At low voltage, the linear mathematics models of AC EO and TW EO were presented and simulated. The experimental and simulation results show TW EO is more efficient and the streamlines are smoother than AC EO.

Hukun Yang Hongyuan Jiang Hongrui Ao Antonio Ramos Reyes Pablo García-Sánchez

School of Mechatronics Engineering,Harbin Institute of Technology,150001,Harbin,PR China Departamento de Electrónica y Electromagnetismo,Universidad de Sevilla,Facultad de Física,Avenida Re

国际会议

The 2nd International Symposium on Systems and Control in Aeronautics and Astronautics(第二届航空航天系统与控制国际会议 ISSCAA 2008)

深圳

英文

313-316

2008-12-10(万方平台首次上网日期,不代表论文的发表时间)