会议专题

Study on effective wall thickness in arid and semi-arid areas

In arid and semi-arid areas, the diurnal and annual temperature ranges are large. Taking reasonable measures of thermal insulation, the indoor thermal environment can be comfort. The traditional dwellings, in arid and semi-arid areas of western China, have energy efficient characteristic, among which Yaodong is the typical representative. In this paper, the temperature in Yaodong wall will be tested and calculated to research the scientific mechanism of energy conservation. And then the effective wall thickness will be calculated by the periodic thermal transfer mechanism. This method offers a theoretical basis for low energy building design in arid and semi-arid areas.

Yaodong dwelling attenuation effective wall thickness

Wang Lijuan Liu Jiaping Liu Yanfeng

Xian University of Architecture and Technology, Xian, Shaanxi, 710055, China

国际会议

2010 International Conference on Digital Manufacturing and Automation(2010 数字制造与自动化国际会议 ICDMA 2010)

长沙

英文

467-470

2010-12-18(万方平台首次上网日期,不代表论文的发表时间)