Optoelectronic System for Measuring Warhead Fragments Velocity
High-speed warhead fragments velocity measurement is one of the key technologies in investigating damage efficiency of warhead. We have designed and constructed a system to accurately determine the velocity of warhead fragments by measuring the time of flight between two parallel laser screens is presented. Each screen is formed by a laser source, a large photodetector and a retro-reflector. Optical output of the laser source is a collimated beam. The beam passes through cylindrical lens and the slit of photodetector reach to retro-reflector .The energy, reflected by retro-reflector; focus on the active area of photodetector. The system utilizes reflected ray by scotchlite retro-reflector as the start and end signal. And utilizes wideband circuit and data acquiring system to condition and sample signals. Experimental results show the system can measurement velocity are within the range from 20m/s to 2000m/s on target area of lm2 and can perform satisfactorily with a wide range from 2000 be tol00.000lx. The measurement system also can be used to test velocity of projectile.
laser screen non-contact measurement fragment velocity retro-reflector externalballistics
Ji Liu Donge Zhao Yangjun Li Hanchang Zhou
National Key Laboratory on Electronic Testing Technology, Taiyuan, 030051, China Education Ministry National Key Laboratory on Electronic Testing Technology, Taiyuan, 030051, China School of Informati National Key Laboratory on Electronic Testing Technology, Taiyuan, 030051, China National Key Laboratory on Electronic Testing Technology, Taiyuan, 030051, China Education Ministry
国际会议
3rd International Photonics & OptoElectronics Meetings(第三届国际光子与光电子学会议 POEM 2010)
武汉
英文
1-5
2010-11-03(万方平台首次上网日期,不代表论文的发表时间)