Analysis on Phosphorus Removal from Domestic Wastewater Treatment Plant by Biological Aerated Filter

Hydrolysis acidification / pre-denitrification biological aerated filter was adopted in an domestic wastewater treatment plant The effluent was accorded with A standard in the Integrated Wastewater Discharge Standard (GB18918-2002) ,in which the effluent phosphorus was demanded below 0.5mg/L. Through analysis on the process biological phosphorus removal, biological method can be found to total phosphorus l.S mg/L. If you reach level to A emissions standards, phosphorus chemical experiment research, finally determined by strategy for the CN pool, point for adding potions FeC13, dosing quantity for 3Smg/L.

biological phosphorus removal chemical phosphorus removal biological aerated filter domestic wastewater

Liu Yin-song Han Hong-jun Xu Chun-yan Wang Bing Li Yu-fei

State Key Laboratory of Urban Water Resource and Environment,Harbin Institute of Technology, Harbin, 150090, China

国际会议

2010 3rd International Conference on Environmental and Computer Science(2010年第三届环境与计算机科学国际会议 ICECS 2010)

昆明

英文

115-118