会议专题

Evaluation for antifreeze of concrete based on method of Bubble parameters

Nowadays we usually use air bubble parameter to evaluate the freeing resistance.This method save time,water and electricity.However,this method is too simple to reduce the accuracy and limit its application.For changing this fact we stood the minimum observation Wire length and standard maintenance age influence on air Bubble parameters.Firstly According to air bladder spacing coefficient of the different traverse wire length,calculate the range and deviation coefficient.Secendly detect the antifreeze degree by rapid freeze-thawing test,finaly set up the regression equation among the air spacing coefficient of 3d,28d and 90d.In conclusion,wire length should take at least 2 times of the now minmum.We cannot directly use the spacing coefficient of bubble in 3d to evaluate the freezing resistance of the concrete structure.But we can use equation y = 0.356x +0.514 to convert that of 90d to 28d and evaluate the freezing resistance of the concrete structure.

Key word concrete air Bubble parameters Wire length standard maintenance age

Lv LiHua Liu JunZhe

Department of Civil Engineering,Northeast Forestry University,Harbin,Heilongjiang,150040,China Faculty of Architectural,Civil Engineering and Environment,Ningbo University,Ningbo 315211,China

国际会议

2010 International Conference of Environment Materials and Environment Management(2010年环境材料与环境管理国际学术会议 EMEM 2010)

哈尔滨

英文

2262-2265

2010-07-24(万方平台首次上网日期,不代表论文的发表时间)