Calculation of Starting Currents and Losses for Damper Bars of Pumped Storage Machines by SFC
For the pumped storage machines started by static frequency converter (SFC), the mathematical model of multi circuits is established considering actual arrangement of the damper bars based on the multi-circuits theory of the electrical machines. Then the mathematical simulation of static frequency converter starting is carried out by MATLAB, and the transient currents and losses of the damper bars are caculated. Finally, a sample machine is given as the example. The result indicates that the stronger the saturation is, the larger the influence on the field current is, but the influence on the torque is very small.
pumped storage machine static frequency converter starting damper bar mathematical mode
ZHANG Yu-zhi
Information and Control Engineering College, Weifang University 261061 Weifang, China
国际会议
2010 2nd International Conference on Signal Processing System(2010年信号处理系统国际会议 ICSPS 2010)
大连
英文
220-223
2010-07-05(万方平台首次上网日期,不代表论文的发表时间)