会议专题

Effect of How PDC Macro Interface Structure on the Performance of the Resistance to Impact

This paper focuses on the research for test method of PDC impact resistance performance. It has been proved that not only can PDC impact resistance be revealed well,but also test time could be shortened greatly afier instead of 0.2kg steel ball with 2kg steel ball. With the improvement method,we test the impact resistance performance of PDC with 5 typical macroscopic interfaces at normal temperature and after heating,such as,planar structure,v-groove,u-groove,ring groove,ring claw-tooth. With SEM,we study on its different impact resistance performance due to different macroscopic interfaces,analyze the reason why PDC impact resistance is different with the changing of PDC macroscopic interface,and find macroscopic interface with multi-plane shape (e.g. ring claw-tooth) plays an unportant role on eliminating the stress of interface.

PDC Macroscopic interface Impact resistance performance Influence

Wenjie Fan Fang liu Chuanxun Zhou

Zhongyuan University of Technology,Zhengzhou 450007,China White Dove (Group) CO, LTD, Zhengzhou 450007, China

国际会议

Frist Annual Meeting on Testing and Evaluation of Inorganic Materials(第一届全国无机材料测试与评价学术年会)

南昌

英文

660-664