会议专题

Research on Power Tracing Methods at Frequencies from 400 Hz to 100 kHz

Proposes a new power tracing method named with RMS-Impedance by comparing the advantages and disadvantages of several wideband power measurement methods, and gives the principles and realizations of RMS-Impedance Method, Three Parameters Method and Three Voltmeters Method. In order to build a wideband power standard, we compare and verify these three methods by experiments, and try a new power tracing approach.

AC power RMS-Impedance method three parameters method three voltmeters method.

Li Yalu Liu Min You Li Chen Aqin

Beijing Orient Institute of Measurement & Test (BOIMT) Department 12,Beijing 100086,China

国际会议

2011 10th International Conference on Electronic Measurement & Instruments(第十届电子测量与仪器国际会议 ICEMI2011)

成都

英文

184-187

2011-08-16(万方平台首次上网日期,不代表论文的发表时间)