会议专题

Study on Over DC Power Line Data Transmission

This study developed a low cost serial data transmission method. By using this method, commonly used data transmission cable can be omitted. The result shows that with baud rate of 9600 bps, stable data transmission can be realized. In order to implant serial data to DC power line, electric circuit was designed to convert serial data into serial data modulated sine signal (carrier signal) which is transmittable over DC power line (coding & decoding). 2 MCUs are included in the circuit, one for modulation, and the other for demodulation. With this feature, MCU can recognize different carrier frequency by simply changing program parameters. The method is now under real environment testing stage in experiment equipment.

sine signal serial data switch circuit modulation demodulation

Zhang Ziyi Yang Zhiqin Zhang Jixiang Duan Kailu

Beijing Union University,Beijing China Beijing Yanke Corp. Beijing China

国际会议

2011 10th International Conference on Electronic Measurement & Instruments(第十届电子测量与仪器国际会议 ICEMI2011)

成都

英文

248-251

2011-08-16(万方平台首次上网日期,不代表论文的发表时间)