Research for Measuring Concentration of Gas/Solid Two Phases Flow

The measuring concentration of Gas/Solid two phases flow is a difficult question in industrial process. The paper introduced an experimental research method and a system for measuring concentration of gas/solid two phases flow based on electrical capacitance tomography. The ECT system was 8 internal electrodes and an ac-based low capacitance measuring circuit. Two flow patterns, i.e. full and half field distribution, and 4 types of concentrations were used to be reconstructed by ECT system. Therefore, the experimental resultants showed that the relationship between the concentration and the average of grey level value of reconstruction image or, normal measured capacitance are monotonous and nonlinear, that means the method of measuring concentration of gas/solid two phases flow is feasible. In addition, the resultants also showed that the ECT system is ability to detect the blocking state of the pipe.

electrical capacitance tomography gas/solid two phases flow concentration measurement.

Wang Yan Lu Decai Li Rui

School of Electric & Information Engineering,Liaoning Institute of Science and Technology,Xianghuai road 176#,Benxi 117004,China

国际会议

2011 10th International Conference on Electronic Measurement & Instruments(第十届电子测量与仪器国际会议 ICEMI2011)

成都

英文

1066-1069

2011-08-16(万方平台首次上网日期,不代表论文的发表时间)