Numerical Research on Rotor Vane Number and Angle of the Vortex Vacuum Pump
This issue presents a horizontal dry high vacuum pump and carried out a series of simulations with FLUENT software. The internal flow and work performance were investigated under different number of blades and different direction of leaning vanes on the rotors. The results showed that different blades greatly influenced the pumping performance,which should be decided by actual sizes. Specifically,this issue selected the best number as forty-three after calculating and optimizing. In the investigations of angles,impellers with none leaning vanes were the best after simulation and comparisons.
Dry high vacuum pump flow characteristics vane number vortex stage FLUENT
LIU Kun WANG Guang-yu BA De-chun ZHANG Zhen-hou LI Pei-yin
School of Mechanical Engineering and Automation,Northeastern University,Shenyang,China,110004 SKY Technology Development Company Ltd. of CAS,Shenyang,China,110168
国际会议
沈阳
英文
332-338
2011-05-22(万方平台首次上网日期,不代表论文的发表时间)