会议专题

Computational Models of Thermal Deformation in Running Vacuum Pump

Due to the demand of pumping mixed gases containing strong corrosive and easily crystallized medium,the inner temperature of running Roots pump are always higher up than 100 centigrade degree. ANSYS software is used to analyze the inner temperature field of dry roots vacuum pump at steady running. The thermal deformation of rotor axis and pump body is calculated and showed in cloud chart and figures through thermostructure coupling analysis,which give a useful reference to design of gearing clearance and further study on leakage flow in the gearing clearance of running pump.

Dry vacuum pump thermal deformation computational models ANSYS

WANG Guang-yu LIU Kun ZHANG Zhen-hou BA De-chun YUE Xiang-ji

School of Mechanical Engineering and Automation,Northeastern University,Shenyang,China,110004 SKY Te School of Mechanical Engineering and Automation,Northeastern University,Shenyang,China,110004 SKY Technology Development Company Ltd. of CAS,Shenyang,China,110168

国际会议

10th International Conference on Vacuum Metallurgy and Surface Engineering,Vacuum Engineering Conference 2011 and Vacuum Consultancy Workshop 2011(第十届国际真空冶金与表面工程学术会议、2011年真空工程学术会议、2011年真空咨询工作会议)

沈阳

英文

368-372

2011-05-22(万方平台首次上网日期,不代表论文的发表时间)