An Analysis Method of Operation State for Boost Converter with Voltage Feedback Control
When system parameters were adjusted, some instability phenomenon could occur in closed-loop DCDC converter. For improving the stability of converter system, an analysis method of operation state for converter was presented based on the discrete model of continuous conduction mode(CCM) Boost converter with voltage feedback control. This method can avoid fussy derivative operation. The steady equation of CCM Boost converter was deduced and the system parameters condition on which closedloop instability phenomenon would occur were analyzed, the condition is appropriate to high frequency Boost converter. Corresponding simulation results were given in this paper.
boost converterst continuous conduction mode discrete model discriminant operation state
Leng Zhaoxia Liu Qingfeng Sun Jinkun Wang Huamin
School of Automation and Information Engineering Xian University of Technology Xian, CHINA
国际会议
2010 International Conference on Circuit and Signal Processing(2010年电路与信号处理国际会议 ICCSP 2010)
上海
英文
64-67
2010-12-25(万方平台首次上网日期,不代表论文的发表时间)