会议专题

Infrared signature measurement of targets accounting for atmospheric attenuation

Infrared radiation signature measurement of targets is one of important ways for target signature acquirement and target recognition. When measuring the infrared signature of a target in the atmosphere, molecules and aerosol particles in the atmosphere would attenuate the infrared radiation from the target, and at the same time, the air path radiation would be added to the target radiation. Therefore, in order to obtain the intrinsic infrared radiation of the target, it is necessary to perform atmospheric correction in the process of target radiation inversion. A model for target radiation measurement and inversion was established, and precision analysis on the model was given. A longwave infrared camera was used to perform infrared signature measurement experiment on an ISDC extended-area blackbody. Based on atmospheric parameters, the atmospheric transmittance and the air path radiation between the blackbody target and the camera were calculated by using the MODTRAN software, for use in atmospheric correction in the target radiation inversion process. The experimental results showed that radiation inversion precisions were about 7.3%~9>3%. Additionally, inversion precision will improve as target temperature rises.

radiation measurement atmospheric transmittance atmospheric attenuation radiation inversion.

YANG Ci-Yin CAO Li-Hua ZHANG Jian-Ping LU Ming

Changchun Institute of Optics, Fine Mechanics and Physics Changchun, China

国际会议

2010 International Conference on Computer,Mechatronics,Control and Electronic Engineering(2010计算机、机电、控制与电子工程国际会议 CMCE 2010)

长春

英文

301-303

2010-08-24(万方平台首次上网日期,不代表论文的发表时间)