The Study on the Flow of the Kerosene in Micro Tube

Experiments have been done to investigate the flow pressure drop and the friction coefficient of the kerosene (RP-3) in micro tube. The result shows that the friction coefficient decreases with the increasing of the Reynolds number, the friction coefficient in micro tube is larger than in traditional channels; in the small tube, the flow transition from laminar to turbulent occur at the critical Reynolds number which is lower than the traditional critical Reynolds number 2300 in conventional ducts.

micro tube the friction coefficient lower than the critical Reynolds number

Zhongzhou Li Huiren Zhu

School of Power and Energy Northwestern Poly-technical Univ Xian, China