Optimization of Calibration Parameters For Hybrid III 5th Female Dummy Neck Calibration Test Based on Taguchi Method

The costly honeycomb used in Hybrid III 5th female dummy neck calibration experiments and the lower rate of successful experiments because of there are many factors affecting neck deceleration characteristic will cause much waste of manpower and finance. We found from lots of tests that calibration temperature, impact velocity of the pendulum, cells of honeycomb and its cut style would affect the calibration results greatly. In this paper we adopted Taguchi method to determine the optimal levels of these factors, combined with S/N ratio and analysis of variance (AN OVA) to discuss the trends how these factors affect the calibration results. Finally we got the optimized parameters of Hybrid HI 5th female neck calibration.

Taguchi method Neck calibration Design of experiments (DOE) Analysis of Variance (ANOVA)

Zhixin Liu Xiaolong Zhang Hong Chen Yongwan Shi

Automotive Testing and Research Institute China Automotive Technology and Research Center Tianjin,China

国际会议

Third International Conference on Information and Computing(第三届信息与计算科学国际会议 ICIC 2010)

无锡

英文

97-100

2010-06-04(万方平台首次上网日期,不代表论文的发表时间)