Effect of Ventilation on Fire Characteristics of Upholstered Furniture
Full-scale fire tests on upholstered furniture were conducted in the ISO 9705 room (3.6m×2.4m×2.4m) at different ventilations. The upholstered furniture had the same size, shape, frame, foam, and cover. Width of intake was transformed in order to transform ventilation conditions of the combustion chamber. The effect of ventilation on the combustion behavior of upholstered furniture was studied, and the relation of peak heat release rate and ventilation factor was analyzed. At the same time, the studies on the effect of size of full-scale upholstered furniture have been conducted in enclosure and large space. Parameters such as heat release rate, smoke production rate, temperature profiles of ceiling and doorway were recorded, the difference in between enclosure and large space of fire property of upholstered furniture were discussed. Meanwhile, the relation of between peak heat release rate and temperature of ceiling was given.
Upholstered Furniture Ventilation Fire Characteristics
ZHU Wuba ZHANG Heping
Nanjing Fire Sergeant Training School, Nanjing 211133, Jiangsu, China State Key Laboratory of Fire Science, USTC, Hefei 230027, Anhui, China
国际会议
The 2010 International Symposium on Safety Science and Technology(2010 安全科学与技术国际会议)
杭州
英文
652-656
2010-10-26(万方平台首次上网日期,不代表论文的发表时间)