会议专题

Microstructures and Properties of Copper-steel Welded Joint by Twin Wire Welding

The paper studies the twin wire butt welding of 6mm-thick T2 copper and Q235 steel plate by using the twin wire consisting of one copper-plated welding wire and one steel welding wire. According to the appearance detection, the weld joint gained is sound in shape without crackles, pores, incomplete fusion and other defects. As shown by the mechanical property, SEM and EDAX and in the metallographic analysis and test, the rupture position of coppersteel welded joint is located in the copper-part HAZ when the tensile strength reaches above 210MPa and Fe content of the welded joint involved in 1# test specimen reaches around 22.78-26.75%, with the hardness achieving between 102~107HB and the weld structure being (+) duplex solid solution.

copper-steel welded joint twin-wire welding mechanical property metallurgical structure composition of weld line

J.Yu B.W.Wu S.B.Zheng K.H.Wang Q.Zhou

School of Materials Science and Engineering, Nanjing University of Science and Technology,Nanjing, 210094

国际会议

The 3rd International Conference on Power Beam Processing Technologies(2010 高能束流加工技术国际会议 ICPBPT 2010)

北京

英文

376-380

2010-10-25(万方平台首次上网日期,不代表论文的发表时间)