Research on Risk Analysis and Automatic Control Methods of Chlorine Chlorination Process Engineering*
This paper briefly introduces chloride chlorination process engineering and analyzes its risk. On the basis of practical investigation and study on large numbers of chemical enterprises involved in chloride chlorination process and combining with a lot of chemical safety experts practical experiences, safety control methods on devices of liquid chlorine cylinder weighing, liquid chlorine gasification, chlorine buffering, chlorination action and accident chlorine absorption are proposed according to its dangerousness. The liquid chlorine cylinder is weighed and auto alarmed by the liquid chlorine cylinder weighing device. Liquid chlorine gasification device uses a coil vaporizer and setting an auto control valve at the steam input side and a temperature display alarm device at the hot water side to make interlocking control. An over-pressure alarm and safety valve are adopted in the chlorine buffering. The automatic control valve, flow controller, over-pressure alarm, over-temperature alarm and over-current alarm are set for interlocking control in the chlorination reaction device. The over-temperature alarm is set for interlocking control in the accident chlorine absorption device
chlorine chlorination process automatic control methods alarm
ZHAO Qingxian GE Xiukun SHAO Hui PAN Fangfang YUAN Xiongjun
School of Environment and Safety Engineering,Changzhou University, Changzhou, Jiangsu 213164, China
国际会议
2010 International Conference on Risk and Reliability Management(2010年风险与可靠性管理国际会议RRM 2010)
北京
英文
51-57
2010-10-23(万方平台首次上网日期,不代表论文的发表时间)