会议专题

Simulation Research on the Control Strategy of Three-phase Four-leg Inverter

The four-leg inverter is able to provide simultaneous power supply for three-phase or single-phase load with symmetrical voltage and constant frequency. The prerequisite is that the four-leg inverter must be controlled appropriately, so the synchronous rotating control strategy based on the decomposition sequence is proposed in this paper. Firstly, the inverters mathematical model was given. Based on the model, control variables are decomposed in the novel decomposition sequence algorithm, and the forward-feed decouple method is adopted in the control system; Secondly, control system parameters are determined. Finally, by experimental results and comparatively analysis, the proposed control method is verified valid and is superior to Proportion-Integration control strategy on traditional synchronous frame.

three-phase four-leg inverter decomposition sequence algorithm feed-forward decouple control

Chen Hongbing Min Jingyan

Department of Physics and Electronic Engineering Xiangfan University Xiangfan City, China Schoole of Department of Physics and Electronic Engineering Xiangfan University Xiangfan City, China

国际会议

The 2010 International Conference on Computer Application and System Modeling(2010计算机应用与系统建模国际会议 ICCASM 2010)

太原

英文

602-606

2010-10-22(万方平台首次上网日期,不代表论文的发表时间)