Design of Fiber-optic High-temperature Sensor Based on Colorimetry

Traditional radiation thermometer is not suitable for such adverse environment like strong electromagnetic interference, strong corrosion, and confined space, etc To overcome the defect of traditional radiation thermometer, a new colorimetric fiber-optic temperature measurement system has been proposed in the present research, and the system meets the requirements for transient-temperature measurement On the basis of describing the working principle of colorimetric temperature measurement, a colorimetric fiber-optic high-temperature sensor has been designed, and the feasibility of the design has been proved through experiments. The design is characterized by low cost and high accuracy, and has a sound prospect with certain application value.

colorimetry planck theorem focus lens solid- state photomutiiplier

GUO Hualing HAO Xiaojian ZHOU Hanchang

National Key Laboratory of Electronic Measurement Technology, School of Information and Communication Engineering, North University of China, Taiyuan 030051, P.R.China

国际会议

The 2010 International Conference on Computer Application and System Modeling(2010计算机应用与系统建模国际会议 ICCASM 2010)

太原

英文

325-328